Modular Reservoir System 

The Modular Reservoir System holds liquids for pipetting with Biomek Pipette Tools and Beckman Coulter Manual Pipettors. Full reservoirs hold 150 mL and do not require a frame. Half and quarter reservoirs, with volumes from 18 mL to 75 mL, require the use of a Reservoir Frame. Each frame can accommodate up to four quarter reservoirs or two half reservoirs, or combinations thereof. All reservoirs are sterile and made of polypropylene.
Part No. Description
372790 Quarter Reservoir, 40 mL, Qty. (40/Case)
534680 Quarter Reservoir, Nonpyrogenic, 40 mL, Qty. (40/Case)
372792 Quarter Reservoir, Divided by Width, 18 mL/Section, Qty. (48/Case)
372788 Quarter Reservoir, Divided by Length, 18 mL/Section, Qty. (48/Case)
372786 Half Reservoir, 75 mL, Qty. (24/Case)
534681 Half Reservoir, Nonpyrogenic, 75 mL, Qty. (24/Case)
372794 Half Reservoir, Divided by Width, 37 mL/Section, Qty. (24/Case)
372784 Full Reservoir, 150 mL, Qty. (12/Case)
534678 Full Reservoir, Nonpyrogenic, 150 mL, Qty. (12/Case)
372795 Reservoir Frame, for Quarter and Half Reservoirs

Biomek 2000 Starter Kit 

Includes a sample of all Beckman Coulter Biomek 2000 labware. Starter Kit is included with the purchase of a new Biomek 2000.
Part No. Description
609082 Biomek 2000 Starter Kit

Pipette Tips 

Beckman Coulter Pipette Tips are manufactured to stringent specifications using quality control procedures that ensure straight, contamination-free and leak-proof pipette tips. Beckman Coulter Pipette Tips are required for use with Biomek Pipette Tools. The P20 and MP20 Tools require either the P20 or P250 pipette tips. The P200L and MP200 Tools require P250 pipette tips. The P1000L Tool requires P1000 pipette tips. Barrier tips reduce the possibility of sample cross-contamination from aerosols, and nonpyrogenic tips are used for endotoxin and other assays requiring the ultimate in bacterial contamination control. All Beckman Coulter pipette tips are made of polypropylene.
Part No. Description
609042 P20 Tips, Sterile, 20 µL, Qty. (96/Rack, 10 Racks)
267603 P20 Tips, Sterile, 20 µL, Pallet, Qty. (10 Racks/Sleeve, 108 Sleeves)
609043 P20 Barrier Tips, Sterile, 20 µL, Qty. (96/Rack, 10 Racks)
267555 P20 Barrier Tips, Sterile, 20 µL, Pallet, Qty. (10 Racks/Sleeve, 108 Sleeves)
609044 P20 Tips, Nonsterile, 20 µL, Qty. (96/Rack, 10 Racks)
609045 P20 Tips, Nonsterile, Bulk, 20 µL, Qty. (1000 tips)
372655 P250 Tips, Sterile, 250 µL, Qty. (96/Racks, 10 Racks)
267027 P250 Tips, Sterile, 250 µL, Pallet, Qty. (10 Racks/Sleeve, 108 Sleeves)
140505 P250 Barrier Tips, Sterile, 125 µL, Qty. (96/Racks, 10 Racks)
267554 P250 Barrier Tips, Sterile, 125 µL, Pallet, Qty. (10 Racks/Sleeve, 108 Sleeves)
534661 P250 Nonpyrogenic Tips, Sterile, 250 µL, Qty. (96/Racks, 10 Racks)
372654 P250 Tips, Nonsterile, 250 µL, Qty. (96/Racks, 10 Racks)
267027 P250 Tips, Nonsterile, 250 µL, Pallet, Qty. (10 Racks/Sleeve, 108 Sleeves)
373689 P250 Tips, Nonsterile, Bulk, 250 µL, Qty. (1000 tips)
373687 P1000 Tips, Sterile, 1000 µL, Qty. (72/Rack, 5 Racks)
267658 P1000 Tips, Sterile, 1000 µL, Pallet, Qty. (5 Racks/Sleeve, 108 Sleeves)
373688 P1000 Tips, Nonsterile, 1000 µL, Qty. (72/Rack, 5 Racks)
267659 P1000 Tips, Nonsterile, 1000 µL, Pallet, Qty. (5 Racks/Sleeve, 108 Sleeves)
609899 P1000 Tips, Nonsterile, Bulk, 1000 µL, Qty. (1000 tips)

Seal & Sample Foil Lids 

Biomek Seal & Sample Aluminum Foil Lids provide a unique solution for multiwell plate sealing. Made of special aluminum foil with a bioinert adhesive backing, the foil lids are pre- sized for titer-plate sealing including Multiwell, Deep-Well and Square-Well Titer Plates. Plates remain sealed at temperature extremes from - 50ºC to +130ºC. Seal and Sample Foil Lids are designed to be easily punctured by automated or manually operated pipette tips to remove sample material from plate wells, eliminating the potential for aerosols and cross-contamination that can result when removing other types of plate-sealing lids. A rubber roller is also available for easy lid placement and to ensure complete sealing.

Part No. Description
538619 Seal & Sample Aluminum Foil Lids, Package of 100
267691 Case of Seal & Sample Aluminum Foil Lids, 50 units of 100 Lids
538618 Roller for Sealing Aluminum Foil Lids, Soft Rubber Roller, 4 in.

Square-Well Titer Plates 

Square-Well Plates provide 2 mL nominal capacity per well in a 96-well format. Ideal for large volume applications such as receptor binding assays. For plate covers, use Biomek Seal & Sample Foil Lids (P/N 538619). Compatible with Beckman Coulter J6 centrifuges.
Part No. Description
140504 Square-Well Titer Plates Polypropylene, Nonsterile, 2 mL/well, Qty. (24/Case)
267602 Square-Well Titer Plates Polypropylene, Nonsterile, 2 mL/well, Pallet, Qty. (24/Case, 50 Units)
609681 Square-Well Titer Plates Polypropylene, Sterile, 2 mL/well, Qty. (24/Case)
267655 Square-Well Titer Plates Polypropylene, Sterile, 2 mL/well, Pallet, Qty. (24/Case, 50 Units)
356980 Adapter for J6, JR3.2 rotor
Holds four plates, one in each position, Qty. (Set of 4)

96-Well Titer Plates 

These multiwell plates are manufactured from specially formulated polystyrene and optimized for maximum protein binding with heterogeneous solid-phase assays such as ELISAs. For plate covers, use Biomek Seal & Sample Foil Lids (P/N 538619).
Part No. Description
609844 96-Well Titer Plates, Nonsterile, without lids, 300 µL, Qty. (100)

Deep-Well Titer Plates and Caps 

Deep-Well plates provide 1 mL nominal capacity per well in a 96-well format. An 8 X 12 cap cover is available for storage and incubation, or use the Biomek Seal & Sample Foil Lids (P/N 538619). Compatible with Beckman Coulter J6 centrifuges.
Part No. Description
267001 Deep-Well Plates, Polystyrene, Nonsterile, 1 mL/well, Qty. (24)
267004 Deep-Well Plates, Polystyrene, Sterile, 1 mL/well, Qty. (24)
267006 Deep-Well Plates, Polypropylene, Nonsterile, 1 mL/well, Qty. (24)
267007 Deep-Well Plates, Polypropylene, Sterile, 1 mL/well, Qty. (24)
267002 Caps, Nonsterile, Qty. (10)
267005 Caps, Sterile, Qty. (10)
267022 Deep-Well Plate, Nonsterile, Natural Color, 1 mL/well, Pallet, Qty. (24/Case, 50 Units)
267020 Deep-Well Plate, Nonsterile, Clear Color, 1 mL/well, Pallet, Qty. (24/Case, 50 Units)
267023 Deep-Well Plate, Sterile, Natural Color, 1 mL/well, Pallet, Qty. (24/Case, 50 Units)
267021 Deep-Well Plate, Sterile, Clear Color, 1 mL/well, Pallet, Qty. (24/Case, 50 Units)
356980 Adapter for J6, JR3.2 rotor, Qty. (Set of 4)
356981 Adapter for J6, JR3.2 rotor, Qty. (Set of 4)

24-Place Tube Rack and Inserts 

The 24-Place Rack allows the use of various-sized glass, polystyrene, polypropylene and polyallomer tubes, Microfuge® tubes and cryovials on the Biomek. To ensure proper tube fit, inserts must be used.

Note: Due to variations among manufacturers, tubes and cryovials should be measured prior to selecting an insert. Measure one inch from the tube bottom and select the insert with the appropriate diameter, or check for size using inserts from your starter kit.

Part No. Description
373661 24-Position Tube Rack, Qty. (1)
373697 13mm Diameter Insert, Blue, Qty. (25/Case)
373698 12mm Diameter Insert, Red, Qty. (25/Case)
373696 11mm Diameter Insert, White (for 1.5 mL Microfuge Tubes), Qty. (25/Case)
373699 10 mm Diameter Insert, Black, Qty. (25/Case)
356980 Adapter for J6, JR3.2 rotor, Qty. (Set of 4)
356081 Adapter for J6, JR3.2 rotor, Qty. (Set of 4)
356981 Adapter for GS-6, GH3.8 rotor, Qty. (Set of 4)

Microfuge­­® Tubes 

These Microfuge tubes are required for use on the Biomek 2000. Specially designed to be compatible with 11 mm inserts (P/N 373696), these tubes with inserts fit into the 24-place Rack (P/N 373661) for use on the Biomek. All tubes have a 1.5 mL capacity and come in packages of 500.
Part No. Description
356090 Polypropylene 1.5 mLTube, Clear, Qty. (package of 500)
356091 Polypropylene 1.5 mLTube, Blue, Qty. (package of 500)
356092 Polypropylene 1.5 mLTube, Green, Qty. (package of 500)
356093 Polypropylene 1.5 mLTube, Yellow, Qty. (package of 500)
356094 Polypropylene 1.5 mLTube, Orange, Qty. (package of 500)
357448 Polyallomer 1.5 mL Tube, Natural, 11 mm x 39 mm, Qty. (package of 500)

Manuals & Tutorials 

Part No. Description
609915 BioWorks™ 3.x Software Reference Manual
609900 Biomek 2000 User's Installation and Operations Binder
Includes: Hardware and Software Installation Guide, Maintance and Troubleshooting Guide, Biomek 2000 User's Guide, and BioWorks™ 3.x Tutorial
609903 Biomek 2000 Hardware and Software Installation Guide
609906 Biomek 2000 Maintenance and Troubleshooting Guide
609909 Biomek 2000 User's Guide
609011 Biomek 2000 Tutorial
609912 BioWorks™ 3.x Tutorial
609927 BioWorks™ 3.x Migration Guide

Basic Instrument Training 

Teaches the operator basic operation and method creation using standard automated pipetting techniques. The training is performed on-site to a maximum of two individual per training session by a specially trained field engineer. Includes a Basic Training Workbook and Certificate of Completion. (One is included with the Biomek Workstation)
Part No. Description
609009 Basic Training

Compliance Services 

Operational Qualification Level 3 (OQ3, also known as Instrument Certification)
Provides instrument system maintenanceand ensures Operational Qualification at suitable intervals as defined by the SOPs. It is currently availabe for instruments covered under Beckman Coulter warrenty and Beckman Coulter Service Agreements. Operational qualification at the time of installation assures regulatory agencies that new instrumentation has been qualified in your laboratory before generating any test results.
Part No. Description
609015 Biomek 2000 Certification (OQ3)
145223 Biomek Eight-Tip Tool Certification (OQ3)
 