Beckman Coulter, Inc.
 

Products

   
   
 
 

  MDQ Cartridges and Accessories

Printer Friendly


Related Product Information

 

 

 

Part No. Description
144660 OpCal Cartridge
144733 UV/VIS Upgrade Kit
149819 P/ACE™ MDQ DAD Upgrade Kit - Consists of DAD detector, DAD optics cable, and DAD board
144738 Blank Cartridge Assembly Kit - Contains cartridge body, 100 x 800 µm aperture, tubing kit, nuts, ferrules, and O-rings
144645 Cartridge Rebuilding Kit - Contains capillary length template, cleaving stone, rebuild instructions, O-rings, installation tool, and tweezers
970297 Cartridge Aperture O-Rings (quantity 2)
144689 Cartridge Tubing Kit - Consists of 20-, 30-, 40-, and 50-cm lengths of heat -formed tubing and all connectors
144717 Cartridge Tube Kit 100 - Cartridge coolant tubing (100 cm total length)
144711 Aperture, 100 x 800 µm (kit of 3)
144712 Aperture, 100 x 200 µm (kit of 3)
144829 EDA Cartridge and Adapter Kit - New EDA cartridge with all tubing, clips, seals, etc., and the adapter couplings. Cartridge is detector bypass type.
149044 Blank Cartridge CE/MS Kit Organic Solvent Resistant Cartridge
144822 EDA Capillary Adapter Assembly - EDA capillary adapter body, adapter nuts, seals, fittings, and tubing kit. Used to make existing MDQ detector window cartridges into EDA. No cartridge included.
144834 EDA Tubing Kit - Precut EDA tubing , buts, O-rings, and ferrules
144866 Double Seals with Clips (pkg. of 4)
144873 Single Seals with Clips (pkg. of 4)
721125 MDQ LIF Cartridge Stabilizer Plug for Use with LIF Detection System - Requires probe guide
721126 MDQ LIF Cartridge Probe Guide for Use with LIF Detection System - Requires stabilizer plug
144672 Electrode Replacement Kit - 2 screws, 20 rings, 2-pt wires
144673 Ejector Replacement Kit
359976 Coolant, 450 mL (quantity 1)

Large Volume Buffer Reservoir Kit 

Part No. Description
144824 Large Volume Buffer Reservoir Kit - 2 large volume buffer reservoirs, 4 buffer reservoir lids, buffer reservoir removal tool
144826 Buffer Reservoir Replacement Lid
144858 Replacement Buffer Reservoir Lid Removal Tool
144865 Buffer Reservoir Replacement O-Rings (qty. 4)

eCAP™ Cartridge With Capillaries (Non-MDQ Systems) 

Each Capillary cartridge below contains a fused-silica capillary and is designed with a prealigned aperture for on -column detection. Circulation ports permit flow of inert heat transfer fluid to ensure efficient temperature control. Capillary lengths listed are effective lengths from inlet to detector.
Part No. Description
727604 Capillary Cartridge
Includes tested fused-silica capillary, 50 cm length, 50 µm ID, 375 µm OD, 100 x 200 µm aperture. Capillaries pretreated with 0.1 N NaOH and run with Beckman Coulter Test Mix, P/N 338425, and Beckman Coulter Run Buffer A, P/N 338426. The test mix electropherogram is included.
727605 Capillary Cartridge
Includes tested fused-silica capillary, 50 cm length, 75 µm ID, 375 µm OD, 100 x 200 µm aperture. Capillaries pretreated with 0.1 N NaOH and run with Beckman Coulter Test Mix, P/N 338425, and Beckman Coulter Run Buffer A, P/N 338426. The test mix electropherogram is included.
727607 High Sensitivity UV Cartridge
Includes tested fused-silica capillary, 50 cm length, 50 µm ID, 375 µm OD, 100 x 800 µm aperture. Capillaries pretreated with 0.1 N NaOH and run with Beckman Coulter Test Mix, P/N 338425, and Beckman Coulter Run Buffer A, P/N 338426. The test mix electropherogram is included.
727606 High Sensitivity UV Cartridge
Includes tested fused-silica capillary, 50 cm length, 75 µm ID, 375 µm OD, 100 x 800 µm aperture. Capillaries pretreated with 0.1 N NaOH and run with Beckman Coulter Test Mix, P/N 338425, and Beckman Coulter Run Buffer A, P/N 338426. The test mix electropherogram is included.
760604 LIF Cartridge - Includes tested fused-silica capillary, 50 cm in length, 75 µm ID, 375 µm OD

eCAP™ Capillaries (Pre-Burned Windows) 

Install in P/ACE™ Capillary Cartridge using Capillary Replacement Kit, P/N 338432, to perform separation and analysis of a variety of samples, including pharmaceuticals, industrial chemical, chiral drugs, nucleic acids, amino acids, proteins, and peptides. Capillaries can be trimmed to optimize speed/resolution.
Part No. Description
338453 Fused-Silica Capillary - 75 µm ID, 375 µm OD, 37 cm total length/20 cm effective length (qty. 3)
338475 Fused-Silica Capillary - 20 µm ID, 375 µm OD, 37 cm total length/20 cm effective length (qty. 3)
338451 Bare-fused silica capillary - qty. 3
338454 Fused-Silica Capillary - 75 µm ID, 375 µm OD, 67 cm total length/50 cm effective length (qty. 3)
338480 eCAP™ ssDNA 100 Capillary - 100 µm ID, 65 cm total length (qty. 1)
241521 eCAP™ SDS 14-200 Coated Capillary - 100 µm ID, 65 cm total length (qty. 1)
477431 eCAP™ DNA Capillary - 100 µm ID, 65 cm total length (qty. 1)
477431 eCAP™ Amine Capillary - 50 µm ID, 65 cm total length (qty. 1)
477432 eCAP™ Amine Capillary - 75 µm ID, 65 cm total length (qty. 1)
477441 ProteomeLab™ Neutral Coated Capillary - 50 µm ID x 45 cm total length

 

Extended length capillaries used for interfacing P/ACE™ with Finnigan MAT or SCIEX mass spectrometers. Install in Capillary Cartridge using Capillary Replacement Kit, P/N 338432.
Part No. Description
360800 CE-MS Capillary - 75 µm ID, 111 cm total length (qty. 3)
360801 CE-MS Capillary - 50 µm ID, 111 cm total length (qty. 3)

Untreated Capillary (No Pre-Burned Window) 

Part No. Description
338472 Untreated Capillary - 5 meters in length, 50 µm ID, 375 µm OD
338473 Untreated Capillary - 5 meters in length, 75 µm ID, 375 µm OD
338474 Untreated Capillary - 5 meters in length, 100 µm ID, 375 µm OD
360804 Untreated Capillary - 5 meters in length, 20 µm ID, 375 µm OD

eCAP™ Blank Capillary Cartridge (Non-MDQ Systems) 

Insert fused-silica or gel capillaries into this cartridge to run on the P/ACE™ system. Can accommodate capillary tubing from 20 cm to 120 cm in length. Requires Capillary Replacement Kit, P/N 338432, and Capillary Tubing.
Part No. Description
727608 eCAP™ Blank Capillary Cartridge - 100 x 200 µm aperture
338449 eCAP™ Blank Capillary Cartridge - 50 x 200 µm aperture
360692 LIF Cartridge Blank
727610 Blank High Sensitivity UV Cartridges - 100 x 800 µm aperture

eCAP™ Capillary Replacement Kit (Non-MDQ Systems) 

Provides materials required to build your own cartridge (requires Capillary Tubing and Blank Cartridge) or rebuild your existing capillary cartridge (requires Capillary Tubing). Includes necessary tools, detailed instructions, and materials for building/rebuilding 25 cartridges. Tools and materials include : capillary alignment plate, cleavingstone, clamps, gaskets, sealants strips, plugs, tools, and capillary retaining tubing.
Part No. Description
338432 Capillary Replacement Kit

Consumables Kit (Non-MDQ Systems) 

Replacement supplies for the Capillary Replacement Kit. This kit includes gaskets, sealant strips, plugs, and capillary retainer tubing as required for building/rebuilding 25 cartridges.
Part No. Description
338431 Consumables Kit

Labware Supplies for P/ACE™ System MDQ 

Part No. Description
144980 Vials, 2 mL (qty. 100)
144657 Vial Holders - Required for use of Micro Vials (qty. 50)
144648 Vial caps, 2 mL (qty. 100) - red cap
970668 Vials, 0.5 mL (qty. 50) - blue cap
144649 Vial Caps, 0.5 mL (qty.50)
144709 PCR Vials (qty.50)
358821 Micro Vial Springs - Required for use of Micro Vials (qty. 10)
144656 PCR Vial Caps (qty. 50) - gray cap
144390 Buffer Tray 36 (2 mL Vials)
144543 Buffer Tray 48 (2 mL Vials)
144544 Buffer Tray 48 (0.5 mL Vials)

Miscellaneous Supplies for P/ACE™ System MDQ 

Part No. Description
144672 Electrode Replacement Kit - 2 screws, 20 rings, 2-pt wires
144647 Coolant Filling Kit - Consists of syringe, coolant fill tool, and connecting tubing
144667 Deuterium Lamp Replacement

Labware Supplies for P/ACE™ 2000-5000 Series 

The Autosampler of the P/ACE™ system accommodates up to 34 vials; 10 in the inner tray (for electrolytes) and 24 in the outer tray (for samples, conditioning fluids and electrolytes). Each vial fits into a vial holder, then into the autosampler. Custom-made vial caps prevent evaporation of buffers and samples during operation.

For oligonucleotide work, Mini Vials fit into the P/ACE™ 4 mL vials using the Mini Vial Springs. For microvolume work, Micro Vials fit into the 4 mL vials using the Micro Vial Springs.

The countertop vial storage rack holds up to 40 vials in holders and 20 micro vials.
Part No. Description
358807 Glass Vials - 4 mL working volume for sample and electrolyte (quantity 100).
358818 Vial Holders - Two pieces fit into P/ACE™ autosampler to hold sample and electrolyte vials (quantity 10).
359079 Vial Caps - Seals vials during run (quantity 50).
360004 Vial Caps - Seals vials for storage (quantity 10)
338487 Mini Vials - For oligonucleotide work, polypropylene, 200-400 µL working volume (quantity 100).
338488 Mini Vial Springs - Required for use of Mini Vials (quantity 50).
358819 Micro Vials - For microvolume work polyolefin, 5-30 µL working volume (quantity 10).
358821 Micro Vial Springs - Required for use of Micro Vials (quantity 10).
359093 Vial Storage Rack - Holds 40 vials and 20 Micro Vials in holders (quantity 1).
359980 Micro Vial Autosampler Kit - Provided with each purchase of a P/ACE™ system. Includes 100 vials, 10 Micro Vials, 10 Micro Vial springs, 40 vial holders, vial storage rack, and 50 vial caps.

Temperature-Controlled Sample Tray Supplies 

Part No. Description
727012 Vial Holder (package of 5)
727011 Ambient Vial Holder for Tray (package of 10)
727013 Polypropylene Vials, 200 µL - For cooled vial holder (package of 100).

Miscellaneous Supplies for P/ACE™ 2000-5000 Series 

Part No. Description
359976 Coolant, 450 mL (quantity 1)
142205 Deuterium Lamp Assembly, P/ACE™ 5000 - Replacement part (quantity 1).
359058 Deuterium Lamp Assembly, P/ACE™ 2000 - Replacement part (quantity 1).
360671 LIF Fiber - Optic Cable (5000) (quantity 1)
927781 Nitrogen Tank Quick Connector (quantity 1)
360643 Primer: Introduction to Capillary Electrophoresis
266924 Primer: Micellar Electrokinetic Chromatography
726388 Primer: Introduction to the Theory and Applications of Chiral Capillary Electrophoresis
727484 Primer: Separation of Proteins and Peptides by Capillary Electrophoresis: Application to Analytical Biotechnology
538703 Primer: Introduction to Quantitative Applications of Capillary Electrophoresis in Pharmaceutical Analysis
607397 Primer: Separation of DNA by Capillary Electrophoresis
725036 Primer: High Performance CE of Carbohydrates

Buffer, Test Mixtures, Reagents and Filters For Work with Free-Solution Capillaries 

Part No. Description
338425 Capillary Performance Test Mixture A - Benzoic acid, p-hydroxybenzoic acid, p-hydroxy-phenylacetic acid (quantity 20 mL).
501333 Performance Test Mix B for MDQ
338426 Capillary Performance Run Buffer A - 100 mM sodium borate, pH 8.3 (quantity 50 mL).
338424 Capillary Regenerator Solution A - 0.1 N sodium hydroxide (quantity 50 mL).
338433 Boric Acid, 0.4 M (quantity 50 mL)
338434 Sodium Tetraborate, 0.1 M (quantity 50 mL)
338437 Capillary Performance Test Kit
338436 Borate Buffer Kit - Includes boric acid solution, 0.4 M, 50 mL sodium tetraborate solution, 0.1 M (quantity 50 mL).

Filters for P/ACE™ 2000-5000 Series and System MDQ 

Purchase of the P/ACE™ system includes 200 nm, 214 nm, 254 nm and 280 nm filters. Additional filters can be purchased for replacement or custom applications and are customer installed.

UV Filters Compatible with P/ACE™ System MDQ 

Part No. Description
144430 Filter, 200 nm
144431 Filter, 210 nm
144437 Filter, 214 nm
144432 Filter, 220 nm
144433 Filter, 230 nm
144438 Filter, 254 nm
144434 Filter, 260 nm
144439 Filter, 280 nm
144435 Filter, 300 nm
144436 Filter, 360 nm

LIF Filters for P/ACE™ 2000-5000 Series LIF Detectors 

Part No. Description
360672 LIF Detector Filter Holder
961640 LIF 488 nm Notch Filter
960323 LIF 520 nm Emission Band Pass Filter
890879 LIF 560 nm Band Pass Filter
725412 LIF 675 nm Emission Band Pass Filter

Validation

Instrument Certification
 

Assures regulatory agencies that instrumentation performs to Beckman Coulter's published specifications. The Instrument Certification Program includes specially trained engineers, calibrated testing equipment traceable to national standards, comprehensive documentation and re-certification after repair when necessary.
Part No. Description
144869 P/ACE™ MDQ Instrument Certification (OQ1)
144870 P/ACE™ MDQ OQ2, No Support Agreement
144688 P/ACE™ MDQ Certification (OQ 3)

Capillary Validation 

Part No. Description
501306 Neutral Capillary Validation Pack
501305 Amine Capillary Validation Pack
 



 

 
 
Home | Products | Customer Support | Resource Center