Microfuge® 22R Refrigerated Microcentrifuge--
 Rotors, Tubes and Accessories


Related Product Information

Microfuge® 22R Interchangeable Rotors
Part No. Description Max Speed, rpm Max. RCF, g Max Accel/Decel (seconds) Volume (mL)
367187
F241.5P Rotor
F241.5P Microfuge Fixed-Angle Polypropylene Rotor with snap-on lid 14,000 17,970 18/19 24 x 1.5 / 2.0
365630
F241.5 Rotor
F241.5 Microfuge Fixed-Angle Aluminum Rotor with aerosol-tight plastic "see-through" lid
15,300 20,940 19/23 24 x 1.5 / 2.0
368894
F301.5 Rotor
F301.5 Microfuge Fixed-Angle Aluminum Rotor with aerosol-tight lid**
14,000 21,920 40/38 30 x 1.5 / 2.0
368898
F40.25 Rotor
F40.25 Microfuge Fixed-Angle Aluminum Rotor with aerosol-tight lid**
14,000 17,500 40/38 40 x 0.25 / 0.40
368882
S241.5 Rotor
S241.5 Microfuge Swinging-Bucket Aluminum Rotor
14,000 16,220 30/33 24 x 1.5 / 2.0
369534
12x8.2 PCR* Tube Strip Rotor
F12x8.2 PCR* Tube Strip Rotor

DS-9036B: F12x8.2 PCR Tube Strip Rotor (PDF Format)

14,000 20,800

38/35

12 x Strips of 8 PCR Tubes (200 µL/Tube)

 

 

Microfuge 22R Rotor Accessories 

Part No. Description
369547 Snap-On Lid for F241.5P Rotor
369549 Snap-On Lid for F241.5 Rotor and F40.25 Rotors
367207 Screw-on Lid Replacement, for F241.5P rotor
365629 Aerosol-tight (screw-on) Lid Replacement, for F241.5 rotor

Microfuge 22R Adapters 

Part No. Description
361247 Adapter for 250/400 µL Microcentrifuge/PCR Tubes (package of 24)
364690 Adapter for 500/750 µL Microcentrifuge/PCR Tubes (package of 12)
364701 Adapter for 1.5/1.8 mL Microcentrifuge Tubes with g-Force > 20,000 x g (set of 12).
For use in the S241.5 and F301.5 rotors.

Microfuge 22R Rotor Replacement Parts 

Part No. Description
365806 Rotor Tie-Down Screw
For use with F241.5, F241.5P, S241.5, F301.5, and F40.25 rotors.
365969 Rotor Tie-Down Screw
For use with F1802B rotor.
365636 T-Handle Wrench
For use with F241.5, S241.5, F301.5, F1802B, and F40.25 rotors.
368246 T-Handle Wrench
For use with F241.5P Rotor
368990 Rotor O-Ring for F40.25 Rotor
368896 Lid O-Ring for F241.5P, F301.5, and F40.25 Rotors
 

* All trademarks are the property of their respective owners. Where applicable, the PCR process is covered by patents owned by Roche Molecular Systems, Inc., and F. Hoffmann-LaRoche, Ltd.

** Validation of microbiological containment was done at an independent, third-party facility (CAMR, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and thus, containment.