We offer product training courses and guides to give you the skills and knowledge you need to operate your clinical laboratory instruments.
See all product training courses and guides ›
Choose your country/region and language
The DxH 900 hematology analyzer delivers accurate and high-confidence results on the first run. With its best-in-class hematology technology, this automated analyzer minimizes slide reviews, maximizes laboratory staff time, and provides significant cost savings. The DxH 900 offers scalable, customized solutions to address the hematology testing needs of high-volume labs.
Quality That Counts
Trust your results—the first time—with high-quality hematology analyzers that deliver precise, accurate results and advanced cellular insights.
Productivity That Liberates
Free up your busy laboratory’s hematology team and empower your staff to focus on samples and tasks that truly need attention
Savings That Empower
Tap into powerful savings to help your lab devote time, budget, and resources where they are needed most
Methodology |
Enhanced Coulter Principle, VCS 360 with DataFusion |
|||||
Parameters |
CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Differential: NE, LY, MO, EO, BA, NRBC, NE#, LY#, MO#, EO#, BA#, NRBC# Retic: RET, RET#, MRV, IRF Body Fluids (Cerebrospinal, Serous, or Synovial): RBC, TNC |
|||||
Throughput (tests per hour) |
Up to 100 samples/hour |
|||||
Sample Volumes |
165 μL aspiration volume; 0.5 ml dead volume. Predilute: 50 μL whole blood into 200 μL of diluent |
|||||
Analytical Measuring Ranges2 |
Whole Blood (CBC) |
|||||
|
Parameters |
Units |
Analytical Measuring Range |
||||
|
WBC |
x103 cells/μL |
0.050–400.000 |
||||
|
RBC |
x106 cells/μL |
0.005–8.500 |
||||
|
HGB |
g/dL |
0.10–25.50 |
||||
|
MCV |
fL |
50.00–150.00 |
||||
|
RDW |
% |
10.00–40.00 |
||||
|
RDW-SD |
fL |
15.00–150.00 |
||||
|
PLT |
x103 cells/μL |
3.0–3000.0 |
||||
|
MPV |
fL |
5.00–25.00 |
||||
|
Body Fluids |
||||||
|
TNC |
cells/mm3 |
20–89,000 |
||||
|
RBC |
cells/mm3 |
1,000–6,200,000 |
||||
Data Management |
Up to 50,000 patient results with histograms, scatter plots, and demographics 100,000 patient results with graphics for power computer |
|||||
Quality Assurance |
QC with Levy-Jennings graph; XB/XM for moving averages, daily check, intelligent quality monitoring, MRV, IRF, customizable calibration and QC reminders and alerts, auto export of QC |
|||||
Acoustic Noise Level |
≤ 60 dBa |
|||||
Radio Frequency and Interference Immunity |
Meet the product level standards EN 61326-1 (Electrical Equipment for Measurement, Control, and Laboratory Use—EMC Requirements), and EN 61326-2-6 (Part 2, Specific Requirements for In-Vitro Diagnostic Devices) |
|||||
Power Consumption |
DxH 900 SPM: 520 W (1775 BTU/hour), Monitor: 35 W (120 BTU/hour), DxH Power Computer: 160 W (546 BTU/hour) |
|||||
Dimensions and weight3 |
Width |
Height |
Depth |
Weight |
||
|
76.2 cm (30 in.) |
176.53 cm (69.5 in.), with cover closed 199.39 cm (78.5 in.), with cover open |
83.82 cm (33 in.), including the removable back panel 80 cm (31.5 in.), excluding the removable back panel |
~292.11 kg (644 lbs.), ~287.12 kg (633 lbs.), |
|||
Additional Clearance |
15.2 cm (6.0 in.) per side of instrument for troubleshooting; 3.8 cm (1.5 in.) behind instrument for sufficient cooling |
|||||
Service |
New Preventative Maintenance (PM) schedule with customer care visits |
Support |
Onboard IFU and Instructional Videos, Automated QC and calibration reminders, PROService |
Analyzer Downtime |
Minimum of 30 minutes in cleaner every 24 hours with automatic daily checks |
Available RUO Parameters4 |
BFM, BFM#, BFP, EGC, EGC#, HLR, HLR#, LHD, MAF, MSCV, PCT, PDW, RDWR, RDWR-SD, RSF, UGC, UGC#, UWROP, WDOP, WNOP, WROP, CPD (refer to reference 4 for additional RUO parameters) |
Research Use Only. Not for use in In Vitro Diagnostic procedures.
2. DxH 900 IFU (PN C06947.AD)
3. DxH 900 ReadMe (PN C53971.AB)
4. DxH 900 RUO Addendum
We offer product training courses and guides to give you the skills and knowledge you need to operate your clinical laboratory instruments.
See all product training courses and guides ›
Our proprietary DataFusion technology incorporates information from the analyzer’s Enhanced Coulter Principle and Volume, Conductivity, and Light Scatter (VCS) WBC differential technology for increased confidence in results and improve flagging.2 RBC and PLT counts include the application of sweep flow to prevent the recirculation of cells behind the aperture preventing cells from re-entering the sensing zone to deliver a more accurate count.
DownloadThe Scopio X100 and X100HT are transforming digital cell morphology analysis with Full-Field Peripheral Blood Smear™ Application and AI-based Decision Support System.
Optimize inventory management and reduce the risk of overexertion and physical stress with Eco Diluent, an 18x concentrated, eco-friendly solution that is 35% lighter than the competitor product.
Streamline processes with the DxH 900 Connected Workcell automated hematology system. Connect up to 3 analyzers with a DxH Slidemaker Stainer II to create a system compatible with a full suite of workflow and clinical informatics.
1. Data drawn from side-by-side evaluation of flagging performance and low confidence results (R for DxH - Beckman Coulter and * for XN - Sysmex), based on 11 hospitals and N=1633 samples. View potential savings model report.
2. Serrando Querol M, Nieto-Moragas J, Marull Arnall A, Figueras MD, Jiménez-Romero O. Evaluation of the New Beckman Coulter Analyzer DxH 900 Compared to Sysmex XN20: Analytical Performance and Flagging Efficiency. Diagnostics (Basel). 2021;11(10). doi:10.3390/diagnostics11101756.