|  | Fully automated, random-access clinical chemistry system with STAT capability | 
        
            |  | Spectrophotometry and potentiometry | 
        
            |  | Endpoint, rate, fixed point and indirect ISE | 
        
            |  | Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE | 
        
            |  | 60 photometric tests + 3 ISE | 
        
            |  | 800 photometric tests/hour; up to 1,200 with ISE | 
        
            |  | Serum, plasma, urine, whole blood (HbA1c) and other fluids | 
        
            |  | Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading | 
        
            |  | In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm | 
        
            |  | Up to 22 positions for STAT samples, barcoded primary tubes | 
        
            |  | 1–25 μL in 0.1 μL increments (1–25 μL for repeats) | 
        
            |  | 60 positions for R1, 48 positions for R2; refrigerated: 4–12°C; handling of 3-shot reagents | 
        
            |  | R1: 15–250 μL; R2: 15–250 μL; in 1 μL increments | 
        
            |  | 120–425 μL | 
        
            |  | Quartz cuvettes | 
        
            |  | Up to 8 minutes, 40 seconds | 
        
            |  | 37°C | 
        
            |  | With rotating paddles after dispensing sample and reagent | 
        
            |  | Direct assay through the reaction cuvette (0–3.0 OD) mono and bichromatic measurements possible | 
        
            |  | 13 different wavelengths between 340–800 nm | 
        
            |  | Comprehensive cleaning with detergents | 
        
            |  | Autocalibration, cooled calibrator positions; master calibration established by two-dimensional barcode on the reagent bottle (>3-point calibration) | 
        
            |  | Auto QC, cooled QC positions | 
        
            |  | Individual and profile test requisition via online, mouse, function keys or touch screen | 
        
            |  | Clot detection and crash prevention for sample and reagent dispenser | 
        
            |  | Full uni- and bi-directional communication possible | 
        
            |  | Windows 7® | 
        
            |  | Sample number: 100,000 samples. Reaction data: 200,000 tests. | 
        
            |  | ANL 1,950x1,280x1,000 | 
        
            |  | 200 V; 208 V; 220 V; 230 V; 240 V; 50 Hz; 60 Hz/3.8 KVA |